title: "Prepare a HALCON Procedure"
description: "Write a HALCON procedure in HDevelop that LumiScan Script Runner can run: declared interface, parameter types, images, handles, file names and protection."
product: "LumiScan Script Runner"
component: "lumiscan-script-runner"
version: "1.0.0"
display_version: "1.0.0.2"
latest_version: true
language: "en"
url: "https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/prepare-a-procedure.html"
---

# Prepare a HALCON Procedure – LumiScan Script Runner

The Script Runner runs HALCON **procedures**. It reads a procedure’s declared interface and builds one node per parameter, so the interface must say what every parameter holds. This guide shows how to get there in HDevelop.

## 1. Make it a procedure

The Script Runner can pass inputs only to a procedure and read only a procedure’s outputs. If your vision logic is an HDevelop program (`.hdev`) with a `main`:

1. In HDevelop select the lines of your logic and choose **Create New Procedure**.
2. Declare the interface: which iconic objects and control values go in and come out.
3. Save the procedure as an **external procedure** (`<name>.hdvp`). The file name is the procedure name.

Rules for the interface:

- Input or output is what the interface declares. The Script Runner never guesses it from the body.
- Every parameter name must be unique within the procedure. A procedure cannot use one name for an input and an output; to carry a value from one run to the next, see [A value carried from run to run](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/modules-groups-and-store.html#carried-value).
- Parameter names become node names in kebab case: `MinScore` becomes `min-score`, `ROIRow` becomes `roi-row`. Two parameters must not give the same node name.
- The output names `status-code`, `status-text` and `package-identifier` are reserved: no output parameter may give one of them.

## 2. Describe every input and output {#parameter-information}

To run a procedure, the Script Runner has to know each of its arguments. It needs two kinds of information:

- **The shape:** which parameters are inputs and which are outputs, which are images (iconic) and which are values (control), their names and their order. The Script Runner reads the shape from the procedure itself; the interface you declared in step 1 is enough.
- **The types:** what each parameter holds. For a value parameter that is integer, real, string or handle, one value or several. For an image parameter it is the pixel types and the channels. HALCON does not store this in the declared interface: a control parameter is a tuple that can hold anything. Without the type, the Script Runner cannot build a node of the right type, check a value the PLC writes, or check an output after a run.

You give the types in one of two ways:

| Approach | Use it when | Where the types are kept |
| --- | --- | --- |
| [1. Parameter documentation](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/prepare-a-procedure.html#from-documentation) | You can edit the procedure in HDevelop. This is the recommended way. | Inside the `.hdvp` file. Nothing else has to be copied with it. |
| [2. Interface file](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/prepare-a-procedure.html#from-interface-file) | The procedure is protected, you do not want to change it, or its documentation is incomplete. | In `<procedure>.interface.json` next to the procedure. Where the file and the documentation disagree, the file wins. |

Both can be mixed: the file only has to give the types the documentation lacks. A parameter that has no type from either refuses the module (`-10002`); the status text names the parameter.

### Approach 1: Export the procedure with parameter documentation {#from-documentation}

HDevelop documents a procedure’s parameters the same way as HALCON’s own operators. The fields are described in the *HDevelop User’s Guide* of HALCON 22.11, section 6.17.8.2 "Parameter Documentation" (in the HALCON help, or `doc` folder of the HALCON installation).

1. Open the procedure in HDevelop and choose **Procedures** > **Edit Procedure Interface** (`Ctrl+Shift+P`, `I`).
2. Open the documentation part of the dialog. It has a tab card for each parameter.
3. For each **control parameter** (value), fill in:
   - **Semantics**, for example `integer`, `real`, `string`, `number`, `angle.rad` or `filename.read`, or a handle type such as `shape_model`;
   - **Type List**: `integer`, `real`, `string` or `handle`;
   - **Multi Value**: `false` for one value, `true` or `optional` for several;
   - **Mixed Types**: leave it at `false`. A parameter that mixes strings and numbers is refused.
4. For each **iconic parameter** (image), fill in:
   - **Semantics** `image`;
   - **Pixel Types**: the pixel types the procedure accepts (`byte`, `uint2`, …);
   - **Multi Channel**: `false` for one channel, `true` for colour.
5. Optionally fill in **Default Value**, **Value Min**, **Value Max**, **Values** and **Description** of each input. The default is the node’s first value, the description goes into the node’s description, and the Script Runner refuses an input outside **Value Min** and **Value Max** before the procedure runs.
6. Save the procedure as an external procedure (`.hdvp`).

HDevelop saves the documentation in the `<docu>` part of the `.hdvp` file, one slot per field:

| Dialog field | Slot | What the Script Runner does with it |
| --- | --- | --- |
| Semantics | `sem_type` | Gives the type when `type_list` is empty (see below); `image`, `region` or `xld` for an iconic parameter; `angle.rad` and `angle.deg` give the unit. |
| Type List | `type_list` | Gives the type of a control parameter; the accepted pixel types of an image. |
| Multi Value | `multivalue` | One value gives a scalar node, several values an array node. |
| Mixed Types | `mixed_type` | `true` or `optional` refuses the parameter. |
| Multi Channel | `multichannel` | One channel or colour. |
| Default Value | `default_value` | The input node’s first value. |
| Value Min, Value Max | `valuemin`, `valuemax` | The range an input is checked against. |
| Values | `value_list` | The suggested values. |
| Description | `description` | The node’s description. |

Which slot decides the type of a control parameter:

- `type_list` decides when it is filled in.
- Only when `type_list` is empty does the Script Runner read the type from `sem_type`, and only from these labels: `integer`; `real`, `number`, `angle.`, `point.`; `string`, `filename*`; the handle labels `handle`, `dict`, `window`, `message`, `message_queue`, `serial`, `socket` and any `*_model`. Any other `sem_type` gives no type.
- One exception: a `type_list` of `integer` alone beside a handle label is read as a handle, with a warning in the log. That is how documentation from before HALCON 18, when handles were integers, describes a model; some of MVTec’s own procedures still do. See [Types from sem_type](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/type-mapping.html#sem-type).

So a procedure needs no interface file when every control parameter has a `type_list`, or one of the `sem_type` labels above, and every image parameter has the `sem_type` `image` (or pixel types in its `type_list`).

This is one parameter of the example `convert_length.hdvp`, which needs no interface file:

```xml
<parameter id="Length">
<default_type>real</default_type>
<default_value>25.4</default_value>
<description lang="en_US">The length to convert.</description>
<mixed_type>false</mixed_type>
<multivalue>false</multivalue>
<sem_type>real</sem_type>
<type_list>
<item>real</item>
</type_list>
<valuemin>0</valuemin>
</parameter>
```

A procedure whose parameters were never documented has only `<parameter id="Length"/>` there. No type can be read from it, and its module is refused until approach 2 gives the types.

### Approach 2: Configure the interface by hand in an interface file {#from-interface-file}

An interface file is a JSON file named `<procedure>.interface.json` in the script folder, next to the procedure. It lists every parameter of the procedure with its type. You do not have to type it from scratch: the Script Runner shows the procedure’s shape in the format of an interface file, and you add the types. The Script Runner can also build the file for you over the Data Layer, see [Building one over the Data Layer](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/interface-file.html#over-the-data-layer).

1. Copy the procedure into the script folder, add a module for it to the application file and restart the app, see [Add a Module](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/add-a-module.html). The module is refused (`-10002` or `-10005`), but its `script/` nodes are there.

2. Read `v1/<module>/script/interface`. It lists every parameter with `group` (`input_iconic`, `output_iconic`, `input_ctrl`, `output_ctrl`), `name`, `position` and `dimension`; each parameter without a type is marked `"typeSource": "missing"`.

3. Save that JSON as `<procedure>.interface.json` next to the procedure. Delete every `typeSource` and the top-level `interfaceHash`, and add the type of each parameter:
   - a control parameter gets `elementTypes` (`["integer"]`, `["real"]`, `["string"]` or `["handle"]`) and, for several values, `"multivalue": "true"`;

   - an iconic parameter gets `"objectClass": "image"`, `pixelTypes` (for example `["byte"]`) and, for colour, `"multichannel": "true"`.

     Optionally add `description`, `unit`, `default`, `min`, `max` and `values`. All fields are listed in [Interface File](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/interface-file.html#parameter).

4. Restart the app. The types changed the interface, so the module reports `-10005`, and its `status/text` gives the new hash (`… now sha256:…`). Copy that hash into the module’s `acceptedInterfaceHash` in the application file and restart again.

5. Read `v1/<module>/status/code` and `script/interface-source`. Expected: `0` and `interface-file` (or `mixed`, when some types still come from the documentation).

When it loads the file, the Script Runner checks it against the procedure, so a file that does not fit is refused (`-10002`) instead of being half applied:

- Every parameter of the procedure must be in the file, and every parameter in the file must be in the procedure. The status text names each one that is missing on either side.
- Each parameter must be in the same group (input or output, iconic or control) and have the same dimension as in the procedure.
- A parameter must not be listed twice.
- Each type must be in the [closed type set](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/type-mapping.html#closed-type-set).

The file matches parameters by name, not by position: reordering the parameters in HDevelop needs no change to the file, but renaming one does. A worked example with a complete file is in [Writing one from the procedure’s shape](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/interface-file.html#from-the-shape).

## 3. Use types the Data Layer can carry

See [Type Mapping](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/type-mapping.html) for the complete table. In short:

- **Numbers and strings** become nodes. One value is a scalar node, several values (`multivalue` `true` or `optional`) an array node.
- **Do not mix strings and numbers** in one parameter: such a parameter is refused.
- **Images** become image groups. Mono8, Mono12, Mono16, RGB8 and BGR8 are carried.
- **Regions and contours (XLD)** are not carried. A region or contour **input** refuses the module. A region or contour **output** gets no node: convert it before `return ()`, for example `region_to_bin` or `paint_region` for an image, `area_center` or `get_region_points` for coordinates, `paint_xld` for a contour.
- **Handles** (`shape_model`, `dict`, any model) never cross the Data Layer. A handle input must be bound to the group’s store; a handle output goes to the store by default. See [Share a Model Between Scripts](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/share-a-model-between-scripts.html).
- **A structured value** is declared with the plain types: a pose is 7 `real` values, a `hom_mat2d` 6.

## 4. Files the procedure reads

A string input of the semantic type `filename` (`filename.read`, …) is resolved inside the script folder: the client writes `blobs.png`, the procedure gets the full path. Put model files, images and other data your procedure reads into the script folder. See [The script folder](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/settings-folder.html#script-folder).

## 5. Leave out the display

The Script Runner runs without a display. By default the display operators (`dev_display`, `dev_set_color`, …) do nothing, and `dev_open_window` and `dev_get_window` fail. Remove window operators from the procedure, or guard them. See `ignoreDisplay` in [engine](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/application-file.html#engine).

## 6. Test it

1. Test the procedure in HDevelop with typical and with bad inputs.
2. For a bad input, raise an error yourself with `throw`: the text arrives in the module’s `run/output/status-text` with code `-10001`.
3. Make sure every output is set on every path through the procedure: an output the procedure never set fails the run with `-10003`.
4. Every output must match its declared type. An integer where a real is declared is converted; anything else fails the run with `-10003`.

## 7. Protect it (optional)

You can lock the procedure with a password in HDevelop. The Script Runner still reads its interface and runs it; the password never reaches the device. Keep an unlocked copy: only the password holder can view or change the body.

If you use an interface file, write it **before** you protect the procedure, from the open procedure.

## Next

Copy the procedure (and its interface file) into the script folder, then [Add a Module](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/add-a-module.html).