# Run Your First Script – LumiScan Script Runner

This tutorial runs the three example procedures that come with the Script Runner. You write inputs, start a run with the `run` handshake, read the outputs, and provoke two errors. It takes about 15 minutes.

You need:

- LumiScan Script Runner installed and started, see [Installing the Script Runner](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/installation.html).
- A Data Layer client that can read and write nodes of LumiScan Keryx, for example your PLC or a test client.

All addresses below start with `hdvisionsystems/lumiscan-script-runner/v1/`.

## The examples

The first start copied three procedures into the script folder, and the application file configures one module for each:

| Module | Procedure | What it does |
| --- | --- | --- |
| `add` | `add_values (: : A, B : Sum, Text)` | Adds two integers. It throws an error when the sum is negative. |
| `blobs` | `count_blobs ( : Binary : ImageFile, MinGray, MinArea : Count, Areas, MeanGray)` | Reads the image file `blobs.png` from the script folder, finds its bright blobs and returns their number, each blob’s area, their mean gray value and a binary image. |
| `convert` | `convert_length (: : Length, FromUnit, ToUnit : Converted, Text)` | Converts a length between mm, cm and m. It throws an error for any other unit. |

`add_values` and `count_blobs` get their parameter types from an interface file next to them (`add_values.interface.json`, `count_blobs.interface.json`). `convert_length` has none: every parameter is documented in HDevelop, and the Script Runner reads the types from the procedure itself. See [Prepare a HALCON Procedure](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/prepare-a-procedure.html).

## 1. Check that the modules are ready

1. Read `add/status/code`, `blobs/status/code` and `convert/status/code`. Expected: `0` (`status/text` says `ready`).
2. Read `add/run/ready`. Expected: `true`.

If a status code is not `0`, look it up in [Status Codes](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/status-codes.html).

## 2. Look at the nodes of a module

Browse `add/`. The Script Runner built these nodes from the interface of `add_values`:

| Node | Type | From |
| --- | --- | --- |
| `add/run/input/a` | INT64 | input parameter `A` |
| `add/run/input/b` | INT64 | input parameter `B` |
| `add/run/output/sum` | INT64 | output parameter `Sum` |
| `add/run/output/text` | STRING | output parameter `Text` |
| `add/run/output/status-code`, `status-text`, `package-identifier` |   | every module |
| `add/run/request`, `ready`, `running`, `done`, `has-error` | BOOL8 | every module |

`add/script/interface` shows the interface as JSON, `add/script/interface-hash` its hash.

## 3. Run `add`

1. Write `40` to `add/run/input/a` and `2` to `add/run/input/b`.
2. Write `true` to `add/run/request`.
3. Wait until `add/run/done` or `add/run/has-error` is `true`. Expected: `done` is `true`.
4. Read the outputs. Expected: `add/run/output/sum` is `42`, `add/run/output/text` is `sum of 40 and 2`, `add/run/output/status-code` is `0`, and `add/run/output/package-identifier` has grown by one.
5. Write `false` to `add/run/request`. Expected: `done` goes back to `false`, `ready` to `true`.

You have just run the handshake a PLC function block runs: `request` is `xExecute`, `running` is `xBusy`, `done` is `xDone`, `has-error` is `xError`, `output/status-code` is `eErrorID`. See [The run Handshake](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/run-handshake.html).

## 4. Provoke a script error

1. Write `-50` to `add/run/input/a`, keep `b` at `2`.
2. Raise `add/run/request` and wait. Expected: `has-error` is `true`, `output/status-code` is `-10001` (script error), and `output/status-text` names the procedure, the program line, the HALCON error number and the text the script threw: `the sum must not be negative`.
3. The outputs keep their values of the last successful run: a failed run writes no output.
4. Lower `request` again.

## 5. Run `blobs`

The inputs of `blobs` start at the defaults declared in its interface file: `image-file` is `blobs.png`, `min-gray` `128`, `min-area` `100`.

1. Raise `blobs/run/request` and wait for `done`.
2. Read the outputs. Expected: `blobs/run/output/count` is `4`, `blobs/run/output/areas` holds four areas, `blobs/run/output/mean-gray` is a real value, and `blobs/run/output/binary/` holds the binary image (`data`, `width`, `height`, `pixel-type` `mono8`).
3. Lower `request`.

## 6. Run `convert`, a procedure without an interface file

1. Read `convert/script/interface-source`. Expected: `documentation`: the types come from the procedure’s HDevelop documentation, not from a file.
2. Read the inputs. They start at the documented defaults: `convert/run/input/length` is `25.4` (FLOAT64), `from-unit` is `mm` and `to-unit` is `cm` (STRING).
3. Raise `convert/run/request` and wait for `done`. Expected: `convert/run/output/converted` is `2.54` and `convert/run/output/text` is `25.4 mm = 2.54 cm`.
4. Lower `request`, write `inch` to `convert/run/input/to-unit` and run again. Expected: `has-error` is `true`, `output/status-code` is `-10001`, and `status-text` ends with the text the procedure threw: `unknown unit: use mm, cm or m`.
5. Write `cm` again and lower `request`.

## 7. Provoke an input error

The interface file of `count_blobs` gives `MinGray` a minimum of `0` and a maximum of `255`.

1. Write `300` to `blobs/run/input/min-gray`.
2. Raise `request` and wait. Expected: `has-error` is `true`, `output/status-code` is `-3` (invalid input), and `status-text` names the input and its range. The procedure did not run.
3. Write `128` again and lower `request`.

## Next steps

- Write your own procedure: [Prepare a HALCON Procedure](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/prepare-a-procedure.html).
- Make it a module: [Add a Module](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/add-a-module.html).