# Share a Model Between Scripts – LumiScan Script Runner

A HALCON handle, such as a shape model, lives in the Script Runner’s memory and never crosses the Data Layer. Procedures that use the same handle run in one **group** and pass it through the group’s **store**. This guide reads a shape model from a file once at start and uses it in every run of a search procedure.

The two procedures:

```
load_model ( : : ModelFile : ModelID)
find_pattern (Image : Overlay : ModelID, MinScore, MaxMatches : Row, Column, Angle, Score)
```

`ModelID` is a `handle` in both (`type_list` `handle`, `sem_type` `shape_model`).

## 1. Put both modules into one group

```json
"modules": [
    {
        "name": "load",
        "procedure": "load_model",
        "group": "line-1",
        "trigger": "start",
        "inputs":  { "ModelFile": { "from": "value", "value": "part.shm" } },
        "outputs": { "ModelID":   { "to": "store", "key": "model" } },
        "acceptedInterfaceHash": "sha256:…"
    },
    {
        "name": "find",
        "procedure": "find_pattern",
        "group": "line-1",
        "trigger": "handshake",
        "inputs":  { "ModelID": { "from": "store", "key": "model" } },
        "acceptedInterfaceHash": "sha256:…"
    }
]
```

What happens:

- `load` has `trigger` `start`: it runs once when the group starts, before any request is served. It has no `run` function and no input or output nodes.
- `ModelFile` gets the fixed value `part.shm`, resolved in the script folder.
- `load` writes its `ModelID` output into the store of group `line-1` under the key `model`. A handle output goes to the store even without the binding, and so does every output of a `start` module; the key is then the parameter name.
- `find` reads `ModelID` from the same key. It gets no node for `ModelID`; its other parameters get nodes: `run/input/image/…`, `run/input/min-score`, `run/input/max-matches`, `run/output/overlay/…`, `run/output/row`, `column`, `angle`, `score`.

Put `part.shm` into the script folder, accept both interface hashes (see [Add a Module](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/how-tos/add-a-module.html)) and restart the app.

## 2. Use it

The PLC calls `find/run` as often as it needs; every run uses the model `load` read at start.

- If `load` fails at start, `load/status/code` is `-10002` and its `status/text` gives the reason. The key stays empty, and every `find` run ends with `-10004` (store value missing); the status text names the key and the module that writes it.
- Before each run the Script Runner checks that the handle taken from the store is still valid and, where the interface gives a semantic type, that it is the right kind of handle. If not, the run ends with `-3` and the procedure does not run.

## Variant: train the model at run time

Replace the start module by a handshake module that trains the model from a camera image:

```json
{
    "name": "train",
    "procedure": "train_model",
    "group": "line-1",
    "outputs": { "ModelID": { "to": "store", "key": "model" } },
    "acceptedInterfaceHash": "sha256:…"
}
```

The PLC calls `train/run` once, then `find/run` as often as it likes. The next `find` after a new `train` uses the new model. A `find` before any `train` ends with `-10004`. The store is written only after a successful run whose outputs passed the output check, so a failed `train` keeps the old model.

## Good to know

- A group has one worker thread. Its modules run one after the other, never at the same time, so a handle is never used by two threads. A request to a module whose group is busy is acknowledged (`running` `true`) and waits in the group’s queue, first in, first out.
- Modules without shared state should not share a group: put them into groups of their own (or leave out `group`), and they run in parallel.
- The store lives in memory only. After a restart of the app the `start` modules fill it again. To keep a trained model across restarts, write it to a file in the procedure (`write_shape_model`) and read it in a start module (`read_shape_model`).
- Procedures written before HALCON 18, and some of MVTec’s own, document a model ID with `type_list` `integer`. Beside a handle label such as `shape_model` the Script Runner reads it as a handle anyway and logs a warning, see [Types from sem_type](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/type-mapping.html#sem-type).

See [Modules, Groups and the Store](https://docs.hdvisionsystems.com/en/lumiscan-script-runner/modules-groups-and-store.html).