Data Layer Reference

All nodes are under hdvisionsystems/lumiscan-script-runner/. The app serves API version 1 only: everything but api-version is under v1/.

Node tree

hdvisionsystems/lumiscan-script-runner/
  api-version                         UINT32, read-only: 1
  v1/
    system/
      settings                        the application file (JSON); writable, see below
      restart-required                BOOL8, read-only
      status-text                     STRING, read-only
      scripts                         STRING (JSON), read-only
      modules                         STRING (JSON), read-only
      groups                          STRING (JSON), read-only
      engine/
        version                       STRING, read-only
        license-valid                 BOOL8, read-only
        licensed-modules              ARRAY_OF_STRING, read-only
        edition, revision, arch       STRING, read-only
        library, halcon-root          STRING, read-only
      licenses/
        current/
          file, type, version         STRING, read-only
          valid                       BOOL8, read-only
          error-text                  STRING, read-only
          modules                     ARRAY_OF_STRING, read-only
          expiration-date, host-id    STRING, read-only
        files                         ARRAY_OF_STRING, read-only
      interface-scan/                 build an interface file, see Interface File
      interface-set-parameter/        each: request, ready, running, done, has-error,
      interface-load/                   input/procedure (STRING) and further STRING inputs,
      interface-export/                 output/status-code, status-text, package-identifier
      interface-save/                   and, but for interface-discard, output/interface (JSON)
      interface-discard/
    <module>/
      status/
        code                          INT32, read-only
        text                          STRING, read-only
      run/                            not for trigger "start"
        request                       BOOL8, written by the client
        ready, running, done, has-error   BOOL8, read-only
        input/
          <parameter>                 one node per value input on a node
          <image>/data, width, height, pixel-type
        output/
          status-code                 INT32, read-only
          status-text                 STRING, read-only
          package-identifier          UINT64, read-only
          <parameter>                 one node per value output on a node, read-only
          <image>/data, width, height, pixel-type
      setting/
        procedure, group, trigger     STRING, read-only
        bindings                      STRING (JSON), read-only
      script/
        interface                     STRING (JSON), read-only
        interface-source              STRING, read-only
        interface-hash                STRING, read-only
        accepted-interface-hash       STRING, read-only
        procedure-hash                STRING, read-only
        required-modules              ARRAY_OF_STRING, read-only

v1/system/

Node Type Content

settings

JSON

The application file. Writing it checks the new content (the same checks as at start), saves it and sets restart-required; a refused write leaves everything as it was. See When changes take effect.

restart-required

BOOL8

true after the settings were changed: every module reports -5 until the app is restarted.

status-text

STRING

The app’s state in words: Initialized; the HALCON licence is not valid: …; No module configured: …; or why it has to be restarted.

scripts

STRING (JSON)

The procedures of the script folder: file, procedure hash, interface hash, interface source and, for a procedure that did not load, the error.

modules

STRING (JSON)

Per module: group, procedure, trigger, state and both interface hashes.

groups

STRING (JSON)

Per group: its modules and the keys of its store. Never a value.

engine/version

STRING

HALCON’s version, for example 22.11.1.0.

engine/license-valid

BOOL8

true when HALCON’s licence is valid.

engine/licensed-modules

ARRAY_OF_STRING

The HALCON modules the licence covers. Empty without a valid licence.

engine/edition, engine/revision, engine/arch

STRING

HALCON’s edition (steady), maintenance revision (for example 4) and architecture (x64-win64).

engine/library

STRING

The path of the halcon.dll the app loaded.

engine/halcon-root

STRING

The HALCON folder (HALCONROOT) as HALCON sees it.

licenses/current/file

STRING

The HALCON licence file in use. HALCON uses one licence: the file bound to this PC or to the plugged HALCON dongle.

licenses/current/type

STRING

runtime or development.

licenses/current/valid

BOOL8

true when the licence in use is valid; the same as engine/license-valid.

licenses/current/error-text

STRING

HALCON’s own message when the licence is not valid; empty otherwise.

licenses/current/version

STRING

The HALCON release the licence is valid for, for example 22.11.

licenses/current/modules

ARRAY_OF_STRING

The HALCON modules the licence covers; the same as engine/licensed-modules.

licenses/current/expiration-date

STRING

permanent, or the date the licence ends.

licenses/current/host-id

STRING

The PC or HALCON dongle the licence is bound to.

licenses/files

ARRAY_OF_STRING

Every licence file HALCON found. HALCON reports details only for the file in use.

interface-scan/, interface-set-parameter/, interface-load/, interface-export/, interface-save/, interface-discard/

functions

Build a procedure’s interface file over the Data Layer, with the same handshake as a module’s run. See Building one over the Data Layer.

v1/<module>/

Node Type Content

status/code, status/text

INT32, STRING

The module’s state, see Module state.

run/…​

The run function, see The run Handshake. The input and output nodes follow the Type Mapping; each node’s description holds the parameter’s description, unit, min, max and default, its display name is the parameter name.

setting/procedure, group, trigger

STRING

The module’s settings. group is the module’s own name when it has no group.

setting/bindings

STRING (JSON)

The module’s inputs and outputs bindings.

script/interface

STRING (JSON)

The interface the module uses, in the format of the interface file, with typeSource per parameter.

script/interface-source

STRING

documentation, interface-file or mixed.

script/interface-hash

STRING

The current interface hash, sha256:….

script/accepted-interface-hash

STRING

The accepted interface hash from the application file.

script/procedure-hash

STRING

The SHA-256 of the procedure file.

script/required-modules

ARRAY_OF_STRING

The HALCON modules the procedure needs, from its interface file. A module whose HALCON licence lacks one reports -4.

A module that is not built (status -10002, -10005) keeps status/, setting/, script/ and the fixed run nodes, but has no input or output parameter nodes.