Type Mapping

Parameters to nodes

Procedure parameter Node Notes

Control, element type integer only

INT64

Control, element types with real (also number, angle., point.)

FLOAT64

An integer the procedure returns for a real output is converted.

Control, element type string (also filename*)

STRING

A file name is resolved inside the script folder.

Any of the above with multivalue true or optional

ARRAY_OF_INT64, ARRAY_OF_FLOAT64, ARRAY_OF_STRING

Control, strings mixed with numbers

refused (-10002)

Control, handle (shape_model, dict, any model)

no node

An input must be bound to the group’s store; an output goes to the store by default. See Modules, Groups and the Store.

Iconic, object class image

image group

<name>/data (RAW), width, height, pixel-type, see Images.

Iconic input, region or contour (XLD)

refused (-10002)

Iconic output, region or contour (XLD)

no node

Convert it in the procedure, for example with region_to_bin.

A vector parameter (dimension 1 or 2) on a node

refused (-10002)

Bind it to the store, or use a tuple with several values instead.

Types from sem_type

When type_list is empty, the type is taken from sem_type where it says one:

  • integer gives an integer;

  • real, angle. and point. give a real, number an integer or a real;

  • string and filename* give a string;

  • the handle labels handle, dict, window, message, message_queue, serial, socket and any *_model (shape_model, ncc_model, …​) give a handle.

Any other sem_type is kept as a label and needs a type_list or an interface file.

A type_list of integer alone beside a handle label is read as a handle, and the log names the parameter with a warning. Before HALCON 18 handles were integers, and some of MVTec’s own procedures still document a model that way, for example ModelID of dev_display_shape_matching_results (type_list integer, sem_type shape_model). Any other type_list is taken as it is.

The node name is the parameter name in kebab case (MinScore → min-score), lower case, only a-z, 0-9, - and _. The original name is the node’s display name. The parameter’s description ends with its unit, min, max and default, for example the lowest gray value (min 0, max 255, default 128). An input node starts at the parameter’s default value.

Images

An image parameter is a group of four nodes:

Node Type Content

data

RAW

The pixels, row by row without padding; 16-bit values little-endian.

width

UINT64

Width in pixels.

height

UINT64

Height in pixels.

pixel-type

STRING

mono8, mono12, mono16, rgb8 or bgr8.

pixel-type Image input becomes Image output from

mono8

byte, one channel

byte, one channel

mono12

uint2, one channel, shifted right by the module’s mono12Shift bits

–

mono16

uint2, one channel

uint2, one channel

rgb8

byte, three channels (r, g, b)

byte, three channels

bgr8

byte, three channels (r, g, b)

–

  • An input image is checked before the procedure runs: a known pixel type, width and height above 0, exactly width × height × bytes per pixel bytes, and a pixel type and channel count the parameter accepts. A failed check ends the run with -3.

  • LumiScan X cameras put their 12 bits at the top of the 16-bit word. Set mono12Shift to 4 for such a module to give the procedure values from 0 to 4095.

  • An image output must be exactly one image of pixel type byte (one or three channels) or uint2 (one channel). Anything else fails the run with -10003: convert it in the procedure (convert_image_type, scale_image_max).

Copy time

Every image is copied into HALCON before the procedure runs, and every image output is copied out of HALCON after it. The copy adds to the run time. For a 5-megapixel frame (2448 × 2048) a development PC took per direction:

pixel-type Copy time per direction

mono8

about 1 to 3 ms

mono16

about 3 to 10 ms

rgb8

about 13 to 27 ms

The time grows with the number of bytes; your PC may be faster or slower. Where the cycle time is tight, prefer mono8, and pass only the images the procedure needs.

The closed type set

HALCON has no user-defined types. The Script Runner, the interface file and the type checks know exactly these names:

  • element types of control values: integer, real, string, handle;

  • object classes of iconic objects: image, region, xld;

  • pixel types: byte, int1, int2, uint2, int4, int8, real, complex, cyclic, direction, vector_field;

  • multiplicity: false (one), true (several), optional;

  • dimension: 0, 1 or 2.

A name outside this set refuses the procedure and names the parameter. sem_type is a free label, not a type: any label is kept.