Accepted interface hash

The interface hash a module’s nodes, and the PLC programs that use them, were built for. Stored as acceptedInterfaceHash in the application file. See Interfaces and Hashes.

Application file

lumiscan-script-runner.json, the settings of the Script Runner: script folder, engine settings and modules. See Application File.

Binding

Where an input comes from (node, store, value) or where an output goes (node, store, both, none). See Bindings.

Control parameter

A HALCON parameter that holds numbers, strings or handles, as opposed to an iconic parameter.

Data Layer

The communication layer the LumiScan apps share. On a PC it is LumiScan Keryx; on ctrlX OS the ctrlX Data Layer.

Group

Modules that share one worker thread and one store. Modules of a group run one at a time.

Handle

A reference to a HALCON object held in memory, such as a shape model or a dictionary. It never crosses the Data Layer.

HDevEngine

MVTec’s library that runs HDevelop procedures inside an application. The Script Runner is built on it.

Iconic parameter

A HALCON parameter that holds images, regions or contours (XLD).

Interface

The declared parameters of a procedure in its four groups: iconic inputs, iconic outputs, control inputs, control outputs, each with name, dimension and type.

Interface file

<procedure>.interface.json, the types of a procedure’s parameters written outside the procedure. See Interface File.

Interface hash

A fingerprint (SHA-256) of a procedure’s interface. It changes when a parameter is added, removed, renamed, moved to another group or retyped, not when parameters are reordered.

LumiScan Key

The USB licence key (WIBU CodeMeter) of the LumiScan products.

Module

One procedure with its nodes and settings under v1/<module>/.

Procedure

An HDevelop unit with a declared interface and a body, stored as <name>.hdvp. A protected procedure is locked with a password: anyone can run it, only the password holder can view or edit it.

Procedure hash

The SHA-256 of a procedure file’s bytes. It changes with every change, also to the body.

Script folder

The folder from which the Script Runner loads procedures, interface files and the files procedures read. See The script folder.

Start module

A module with trigger start: it runs once when its group starts, for example to read a model into the store.

Store

A group’s values held in memory by key: handles, tuples, images. See Modules, Groups and the Store.