Glossary
- Accepted interface hash
-
The interface hash a module’s nodes, and the PLC programs that use them, were built for. Stored as
acceptedInterfaceHashin the application file. See Interfaces and Hashes. - Application file
-
lumiscan-script-runner.json, the settings of the Script Runner: script folder, engine settings and modules. See Application File. - Binding
-
Where an input comes from (
node,store,value) or where an output goes (node,store,both,none). See Bindings. - Control parameter
-
A HALCON parameter that holds numbers, strings or handles, as opposed to an iconic parameter.
- Data Layer
-
The communication layer the LumiScan apps share. On a PC it is LumiScan Keryx; on ctrlX OS the ctrlX Data Layer.
- Group
-
Modules that share one worker thread and one store. Modules of a group run one at a time.
- Handle
-
A reference to a HALCON object held in memory, such as a shape model or a dictionary. It never crosses the Data Layer.
- HDevEngine
-
MVTec’s library that runs HDevelop procedures inside an application. The Script Runner is built on it.
- Iconic parameter
-
A HALCON parameter that holds images, regions or contours (XLD).
- Interface
-
The declared parameters of a procedure in its four groups: iconic inputs, iconic outputs, control inputs, control outputs, each with name, dimension and type.
- Interface file
-
<procedure>.interface.json, the types of a procedure’s parameters written outside the procedure. See Interface File. - Interface hash
-
A fingerprint (SHA-256) of a procedure’s interface. It changes when a parameter is added, removed, renamed, moved to another group or retyped, not when parameters are reordered.
- LumiScan Key
-
The USB licence key (WIBU CodeMeter) of the LumiScan products.
- Module
-
One procedure with its nodes and settings under
v1/<module>/. - Procedure
-
An HDevelop unit with a declared interface and a body, stored as
<name>.hdvp. A protected procedure is locked with a password: anyone can run it, only the password holder can view or edit it. - Procedure hash
-
The SHA-256 of a procedure file’s bytes. It changes with every change, also to the body.
- Script folder
-
The folder from which the Script Runner loads procedures, interface files and the files procedures read. See The script folder.
- Start module
-
A module with
triggerstart: it runs once when its group starts, for example to read a model into the store. - Store
-
A group’s values held in memory by key: handles, tuples, images. See Modules, Groups and the Store.