Requirements

PC

Operating system

Windows 11 (64 bit) or Ubuntu 24.04 (64 bit, x86-64)

HALCON

MVTec HALCON 22.11 (Steady), any 22.11.x maintenance release, with a runtime licence: on Windows installed for all users of the PC, on Ubuntu set up for the user who starts the Script Runner. No other HALCON release, older or newer, see HALCON 22.11 only. HALCON is not part of the Script Runner’s installer or package: the Script Runner uses the HALCON installation on the PC. Install HALCON before the Script Runner, see Installing the Script Runner.

Data Layer

LumiScan Keryx on the same PC. The Script Runner connects to it at start.

Licence

The LumiScan Key, see Licence

This version runs on Windows 11 and on Ubuntu 24.04.

HALCON 22.11 only

This version of the Script Runner is built for HALCON 22.11 and runs only with HALCON 22.11. Any 22.11.x maintenance release works; any other release does not, neither an older one (for example 20.11) nor a newer one (for example 24.11). The reason is HALCON itself: MVTec keeps HALCON’s libraries binary compatible within one release only, and a program built for one release has to be rebuilt for the next.

  • At start the Script Runner checks the release of the HALCON libraries it loaded, before it calls HALCON: halcon.dll, halconcpp.dll and hdevenginecpp.dll on Windows, libhalcon.so, libhalconcpp.so and libhdevenginecpp.so on Ubuntu. If one is of another release, it stops, and its log names each library with its version and folder, see Troubleshooting.

  • The Windows installer checks only that HALCON is installed, not its release.

  • Several HALCON releases on one PC are possible, but the Script Runner uses the one whose library folder comes first: on Windows the bin\x64-win64 folder on PATH, on Ubuntu the lib/x64-linux folder on LD_LIBRARY_PATH. That must be HALCON 22.11.

  • The HALCON licence must be valid for HALCON 22.11. A licence for a newer HALCON release is usually valid for older releases too; ask MVTec or your HALCON distributor.

  • A newer HALCON release needs a new version of the Script Runner, built for it.

Your procedures

  • HALCON procedures (.hdvp) that use only operators of HALCON 22.11. A procedure saved with a newer HDevelop (for example 26.05) loads and runs, because the file format is the same; it fails only if it uses an operator that HALCON 22.11 does not have. Test such a procedure with HALCON 22.11 before you put it on the device.

  • Protected procedures (locked with a password in HDevelop) work like open ones: the Script Runner reads their interface and their documentation and runs them, without the password.

  • Every parameter has a type: from the procedure’s documentation in HDevelop or from an interface file. See Prepare a HALCON Procedure.

  • The HALCON modules the procedures use must be in your HALCON runtime licence.

Licence

Two licences are needed on the PC:

  • LumiScan Script Runner: the LumiScan Key (a CodeMeter USB key; WIBU CodeMeter, firm code 6000380, product code 9063), plugged into the PC. The PC needs the CodeMeter Runtime 9.00 or newer (from WIBU-SYSTEMS, wibu.com).

  • HALCON runtime: the HALCON runtime licence (a dongle or a licence file) from MVTec or your HALCON distributor. Without a valid HALCON licence the Script Runner starts, but no module runs: every module reports -4, and system/engine/license-valid is false.

For licences, contact HD Vision Systems at licenses@hdvisionsystems.com.