First Image in 10 Minutes
You end with an image and a point cloud of your LumiScan X on screen, and both saved as files. Six steps; each one ends with Done when and points to the next.
| Working with another camera than a LumiScan X, or with a ctrlX CORE? Use Your First Industrial Vision Application instead: it starts with the Cam Driver, which connects GenICam cameras. |
Step 1 of 6 - Check the system requirements
1 Requirements · 2 Install · 3 Connect · 4 Configure · 5 Capture · 6 Save
You need:
-
the LumiScan X and a 24 V DC power supply - or Power over Ethernet from a PoE port or a PoE injector
-
an Ethernet cable CAT6A, S/FTP shielded, M12 male to RJ45 male, and for the 24 V supply the 5-pin sensor/actuator cable
-
a computer with at least an Intel i5 2.4 GHz, 8 GB RAM, an NVIDIA GTX 1650 and an Intel Ethernet Adapter I210 (or better), with the operating system listed in Software Requirements
-
the LumiScan software installer and your LumiScan Key (the USB licence key)
Done when: everything on the list is on your desk.
Next: Step 2 - Install the software
Step 2 of 6 - Install the software
1 Requirements ✓ · 2 Install · 3 Connect · 4 Configure · 5 Capture · 6 Save
-
Install CodeMeter Runtime 9.00 or later and plug in the LumiScan Key, as described in Installing CodeMeter Runtime.
-
Close all open applications and run
Installer_LumiScanX_<version>.exe. -
Accept the licence terms, keep or change the installation folder, and click Install, OK and Finish.
Details: Installation.
Done when: Start → HD Vision Systems → LumiScan Viewer exists.
Next: Step 3 - Connect the camera
Step 3 of 6 - Connect the camera
1 Requirements ✓ · 2 Install ✓ · 3 Connect · 4 Configure · 5 Capture · 6 Save
Choose one way to power the camera:
-
24 V power supply: screw the M12 plug of the Ethernet cable into the 8-pin socket on the back of the camera (hand-tight, no pliers), connect the RJ45 end to the computer, screw the sensor/actuator cable to the 5-pin socket and connect the 24 V supply.
-
PoE port on the computer: connect the Ethernet cable from the 8-pin socket to the PoE port.
-
PoE injector: computer → injector In, injector Out → 8-pin socket, then plug in the injector.
| Operate the camera with 24 V nominal voltage only, from a supply that meets the SELV and LPS requirements. See Installation for all safety notes. |
Done when: about 30 seconds after power-on the camera has started.
Next: Step 4 - Configure the connection
Step 4 of 6 - Configure the connection
1 Requirements ✓ · 2 Install ✓ · 3 Connect ✓ · 4 Configure · 5 Capture · 6 Save
-
Network adapter: in the Windows Ethernet settings of the port the camera is on, open Configure → Advanced and set jumbo frames to Maximum (9014 bytes), Receive Buffers and Transmit Buffers to 2048. See Network Settings.
-
Firewall: start the LumiScan Viewer. When Windows asks whether it may access the network, allow it - otherwise the camera is not found. See Windows Firewall.
-
Camera IP address: in the LumiScan Viewer open Menu → IP Configuration, click Refresh, select the camera, enable Static IP, enter an address in the subnet of your network adapter and click Apply. A static IP is strongly recommended over DHCP. See Camera IP Configuration.
-
Calibration file: in the Calibration section, enter the camera’s
.hdvcalfile; by default the files are inC:\ProgramData\HD Vision Systems GmbH\calibration.
Done when: the camera is listed and selected in the LumiScan Viewer, with its calibration file.
Next: Step 5 - Capture an image
Step 5 of 6 - Capture an image
1 Requirements ✓ · 2 Install ✓ · 3 Connect ✓ · 4 Configure ✓ · 5 Capture · 6 Save
-
Click the green triangle (start capturing). The image appears in the viewer; the thirteen preview images at the edge switch between the cameras of the LumiScan X.
-
Open the Point Cloud tab to see the 3D data; scroll to zoom, drag with the left mouse button to rotate, with the right one to move.
-
If the image is too dark or too bright, or the point cloud is sparse, adjust exposure and depth range in the settings panel, see Camera Settings Configuration.
Done when: you see your object as an image and as a point cloud.
Next: Step 6 - Save the capture
Step 6 of 6 - Save the capture
1 Requirements ✓ · 2 Install ✓ · 3 Connect ✓ · 4 Configure ✓ · 5 Capture ✓ · 6 Save
-
In the settings panel under Capture, choose what to export: Capture Center View for the image of the centre camera, Capture .ply/.pcd Point Cloud for the point cloud. The default folder is
C:\Users\<user>\HDVisionSystems\LumiScan\export. -
Click the photo icon to export the current capture. (The record icon exports every frame until you click it again - at 6 FPS that is 360 frames per minute.)
See Data Export.
Done when: the image and the point cloud are files in the export folder - your first LumiScan X capture.
What next
-
Pick parts with a robot: LumiScan VGR uses the LumiScan X.
-
All camera settings, filters and the trigger inputs: the LumiScan X manual.
-
Something did not work: the LumiScan X section of the FAQ.